Analysis of Noise Control of a 220 kV Indoor Substation

  

  • Received:2013-05-28 Revised:2013-07-09 Online:2013-12-18 Published:2013-12-18

浅析220 kV室内变电站的噪声控制

陈晓东 1,  陈锦栋 2   

  1. ( 1. 上海市电力公司  电力经济技术研究院  建设管理中心,  上海  200082;2. 上海市电力公司  物资供应公司  新电工程分公司,  上海  200438 )
  • 通讯作者: 陈锦栋

Abstract:

Abstract: This paper described the characteristics, major noise source, noise intensity, frequency characteristics of the 220kV indoor substation. It analyzed the noise propagation of the 220kV indoor substation. Systematically analyzed the noise control measures of the 220kV indoor substation, and briefly described an engineering example, which can be reference to the same project.

摘要:

通过对多个220 kV室内变电站的调研和噪声测试分析,论述220 kV室内变电站的特点、主要噪声源、噪声源的源强、频率特性,剖析其噪声传播影响,对220 kV室内变电站的噪声控制措施进行比较分析,并简要介绍一个工程实例,可供同类工程参考。

关键词: 声学, 室内变电站, 变压器, 电磁噪声, 噪声控制